CCTV Installation Material BOM Estimator

Estimate CCTV installation material Bill of Materials (BOM): Cat6 UTP cable boxes, RJ45 modular plugs, junction boxes, conduit pipes, and cable ties.

Input Parameters

Try Example:
m

Calculation Results

totalCams
16
indoorCams
10
outdoorCams
6
avgCableM
35
useConduit
true
totalCableMeters
644
cableBoxes305m
3
rj45Count
40
junctionBoxes
16
pipaConduitBatang
167
flexibleHoseRoll
1
cableTiePacks
4
bomItems
[{"item":"Kabel UTP Cat6 Pure Copper (Box @ 305m)","itemEn":"Cat6 Pure Copper UTP Cable (Box @ 305m)","qty":3,"unit":"Box","unitEn":"Boxes","note":"Total 644 meter (termasuk 15% slack plafon & rak)","noteEn":"Total 644 meters (including 15% ceiling/rack termination slack)"},{"item":"Konektor RJ45 Cat6 + Plug Boot Modular","itemEn":"RJ45 Cat6 Modular Connectors + Strain Relief Boots","qty":40,"unit":"Pcs","unitEn":"Pcs","note":"2 ujung per tarikan + 25% cadangan gagal crimping","noteEn":"2 terminations per run + 25% field crimping failure allowance"},{"item":"Duradus / Junction Box Waterproof 10×10 cm","itemEn":"Waterproof Junction Box 10×10 cm (Duradus)","qty":16,"unit":"Unit","unitEn":"Units","note":"1 kotak pelindung sambungan PoE & pigtail per kamera","noteEn":"1 enclosure protecting PoE connection & pigtails per camera point"},{"item":"Pipa Conduit PVC 20mm High Impact (@ 2.9m)","itemEn":"PVC 20mm High-Impact Conduit Pipe (@ 2.9m)","qty":167,"unit":"Batang","unitEn":"Sticks","note":"Proteksi 75% jalur kabel ekspos & outdoor","noteEn":"Physical protection across 75% of exposed & outdoor cable paths"},{"item":"Pipa Fleksibel Corrugated 20mm (Roll @ 25m)","itemEn":"Flexible Corrugated Hose 20mm (Roll @ 25m)","qty":1,"unit":"Roll","unitEn":"Rolls","note":"±1.2 meter fleksibel drop dari plafon ke kamera","noteEn":"±1.2 meters flexible drop from ceiling down to camera mount"},{"item":"Kabel Ties Nylon 200mm / 250mm (Pack @ 100 pcs)","itemEn":"Nylon Cable Ties 200mm / 250mm (Pack @ 100 pcs)","qty":4,"unit":"Pack","unitEn":"Packs","note":"Kerapian jalur kabel di atas plafon dan rak server","noteEn":"Bundling and dressing inside ceiling trays and rack enclosures"}]
summaryText
Daftar Kebutuhan Material Instalasi CCTV (BOM) – InfraCalc.id Total Kamera : 16 Unit (10 Indoor Dome + 6 Outdoor Bullet) Kabel UTP Cat6 : 644 Meter (termasuk 15% slack) -> Beli 3 Box (@ 305m) Konektor RJ45 : 40 Pcs (Disarankan menyiapkan minimal 1 Pack isi 50/100 pcs) Junction Box : 16 Pcs (Kotak Pelindung Sambungan PoE Waterproof) Pipa Pelindung : 167 Batang Pipa Conduit 20mm + 1 Roll Pipa Fleksibel Aksesoris Bantu : 4 Pack Kabel Ties + Isolasi Listrik Nitto/3M + Fisher & Sekrup S6

How to Use This Tool

  1. Enter the planned quantity of indoor dome cameras and outdoor bullet/PTZ camera endpoints.
  2. Specify estimated average cable run distances from the PoE switch or NVR to each camera location in meters.
  3. Toggle whether cable runs require PVC conduit piping or open tray/clip routing, then review the finalized procurement material breakdown.

Worked Example: 16-Camera Commercial Office Project (35m Span)

Worked example: A project with 16 cameras (10 Indoor + 6 Outdoor) at 35m average span requires 644 meters of Cat6 cable (Procurement: 3 Boxes @ 305m). Accessory requirements: 40 RJ45 plugs, 16 waterproof junction boxes, 167 conduit sticks (20mm), 1 flexible hose rolls, and 4 packs of nylon cable ties.

Example Input
{
  "indoorCams": 10,
  "outdoorCams": 6,
  "avgCableM": 35,
  "useConduit": true
}
Calculated Output
totalCams:
16
indoorCams:
10
outdoorCams:
6
avgCableM:
35
useConduit:
true
totalCableMeters:
644
cableBoxes305m:
3
rj45Count:
40
junctionBoxes:
16
pipaConduitBatang:
167
flexibleHoseRoll:
1
cableTiePacks:
4
bomItems:
[{"item":"Kabel UTP Cat6 Pure Copper (Box @ 305m)","itemEn":"Cat6 Pure Copper UTP Cable (Box @ 305m)","qty":3,"unit":"Box","unitEn":"Boxes","note":"Total 644 meter (termasuk 15% slack plafon & rak)","noteEn":"Total 644 meters (including 15% ceiling/rack termination slack)"},{"item":"Konektor RJ45 Cat6 + Plug Boot Modular","itemEn":"RJ45 Cat6 Modular Connectors + Strain Relief Boots","qty":40,"unit":"Pcs","unitEn":"Pcs","note":"2 ujung per tarikan + 25% cadangan gagal crimping","noteEn":"2 terminations per run + 25% field crimping failure allowance"},{"item":"Duradus / Junction Box Waterproof 10×10 cm","itemEn":"Waterproof Junction Box 10×10 cm (Duradus)","qty":16,"unit":"Unit","unitEn":"Units","note":"1 kotak pelindung sambungan PoE & pigtail per kamera","noteEn":"1 enclosure protecting PoE connection & pigtails per camera point"},{"item":"Pipa Conduit PVC 20mm High Impact (@ 2.9m)","itemEn":"PVC 20mm High-Impact Conduit Pipe (@ 2.9m)","qty":167,"unit":"Batang","unitEn":"Sticks","note":"Proteksi 75% jalur kabel ekspos & outdoor","noteEn":"Physical protection across 75% of exposed & outdoor cable paths"},{"item":"Pipa Fleksibel Corrugated 20mm (Roll @ 25m)","itemEn":"Flexible Corrugated Hose 20mm (Roll @ 25m)","qty":1,"unit":"Roll","unitEn":"Rolls","note":"±1.2 meter fleksibel drop dari plafon ke kamera","noteEn":"±1.2 meters flexible drop from ceiling down to camera mount"},{"item":"Kabel Ties Nylon 200mm / 250mm (Pack @ 100 pcs)","itemEn":"Nylon Cable Ties 200mm / 250mm (Pack @ 100 pcs)","qty":4,"unit":"Pack","unitEn":"Packs","note":"Kerapian jalur kabel di atas plafon dan rak server","noteEn":"Bundling and dressing inside ceiling trays and rack enclosures"}]
summaryText:
Daftar Kebutuhan Material Instalasi CCTV (BOM) – InfraCalc.id Total Kamera : 16 Unit (10 Indoor Dome + 6 Outdoor Bullet) Kabel UTP Cat6 : 644 Meter (termasuk 15% slack) -> Beli 3 Box (@ 305m) Konektor RJ45 : 40 Pcs (Disarankan menyiapkan minimal 1 Pack isi 50/100 pcs) Junction Box : 16 Pcs (Kotak Pelindung Sambungan PoE Waterproof) Pipa Pelindung : 167 Batang Pipa Conduit 20mm + 1 Roll Pipa Fleksibel Aksesoris Bantu : 4 Pack Kabel Ties + Isolasi Listrik Nitto/3M + Fisher & Sekrup S6

Core Concept & Engineering Notes

Compiling an accurate and exhaustive Bill of Materials (BOM) for physical CCTV surveillance installation constitutes a foundational prerequisite for overall budgetary control and efficient operational field execution. A pervasive contractor oversight involves calculating pure two-dimensional straight-line distances from architectural floor plans while neglecting vertical ceiling drops, wall perimeter corners, and essential service slack loops at both camera mounts and NVR rack terminations. Structured telecommunications cabling engineering mandates incorporating an absolute minimum 15% slack allowance into every individual cable pull. This service slack prevents mechanical conductor tension, facilitates clean patch panel dressing inside server enclosures, and permits future physical relocation of camera bodies without requiring full cable replacement. Because standard commercial UTP cable is packaged in 305-meter (1,000-foot) pull boxes, fractional requirements must ceil to whole boxes to avoid unusable short cable remnants. Auxiliary hardware items require similarly disciplined procurement forecasting. Modular RJ45 plugs demand dual terminations per run augmented by a 25% failure contingency reserve for field crimping defects. Deploying 20mm high-impact PVC conduit piping (standardized at 2.9 meters per stick) shields structural wiring against rodent damage and environmental ultraviolet degradation, while weatherproof junction enclosures (duradus boxes) isolate female RJ45 couplers against corrosive atmospheric humidity. This calculator automates complete hardware material requisitions for any CCTV deployment.

How It Was Calculated (Formulas & Steps)

Frequently Asked Questions (FAQ)

Why is a waterproof junction box (duradus) mandatory at every camera location?

Junction boxes protect modular RJ45 couplers and camera pigtail connectors against dust ingress, rainwater, and humidity condensation that cause pin corrosion and PoE electrical shorts. They also provide neat concealment for cable slack, delivering tamper-resistant aesthetics.

When is rigid PVC conduit piping mandatory for CCTV cabling?

Rigid conduit is mandatory across outdoor areas exposed to direct UV sunlight, above false ceilings prone to rodent infestation, inside industrial factories, and on exposed vertical wall drops to safeguard cables from physical impact while maintaining clean commercial aesthetics.

What is the standard length of a Cat6 UTP cable box and why should short leftover pieces not be spliced?

A standard commercial pull box contains 305 meters (1,000 feet) of UTP cable. Splicing leftover scrap wire using inline barrels or manual twisting is strictly prohibited in data cabling because it degrades the 100-Ohm characteristic impedance, introduces return loss reflections, and causes packet drops.

References & Notes

Last updated: Content Status: Draft (Pending Editorial Review)

Note: Results above are mathematical estimates based on standard formulas. Always verify against official vendor documentation and site conditions before production deployment.